Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Şekeroğlu, Mehmet Ali" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    The Effect of ChromaGen Contact Lenses on Corneal Clarity: A Corneal Densitometry
    (2022) İlhan, Çağrı; Şekeroğlu, Mehmet Ali; Doğuizi, Sibel; Yilmazbas, Pelin
    Objectives: The purpose of this study is to investigate the effect of ChromaGen contact lens (CCL) on corneal clarity, expressed through the measurement of corneal densitometry (CD) values. Methods: This study included 22 eyes of 22 patients with congenital red-green color vision deficiency who were admitted to our clinic for the CCL trial. After a detailed ophthalmological examination and CD measurement with Pentacam HR (Oculus Optikgerate GmbH, Wetzlar, Germany), the most appropriate CCLs were defined through pseudoisochromatic plates and inserted for 2 h. The CD measurement was repeated after the removal of the CCL. Comparison was made of CD values before and after the insertion of the most appropriate CCL. The after-CCL/before-CCL ratio was calculated, and the effect of CCL type on this ratio was investigated. Results: The after-CCL values were higher in the anterior, central, posterior, and total thickness of the 0–2 mm concentric zone (p=0.044, p=0.040, p=0.021, and p=0.032, respectively) when compared to the before-CCL values. There was no statistically significant difference between before-CCL and after-CCL values in any layer of the 2–6, 6–10, and 10–12 mm concentric zones (p>0.05, for all). After-CCL/before-CCL ratios were similar in the Magenta2 (M2), Magenta3 (M3), and Violet3 (V3) types of CCLs (p>0.017). Conclusion: Usage for 2 h of CCL was observed to increase CD values in all layers of the 0–2 mm concentric zone irrespective of the type of CCL. Further studies with longer follow-up are required to determine the long-term effects and detect differing effects of CCL with different base curves.

| Hatay Mustafa Kemal Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Hatay Mustafa Kemal Üniversitesi, Hatay, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim