Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Bozdemir, Esin" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    In Vivo Performance of Two Devices for Occlusal Caries Detection
    (Mary Ann Liebert, Inc, 2013) Bozdemir, Esin; Karaarslan, Emine Sirin; Ozsevik, A. Semih; Cebe, M. Ata; Aktan, Ali Murat
    Objective: The aim of this in vivo study was to compare the performance of light-emitting diode (LED)- and laser fluorescence (LF)-based devices with that of visual inspection (VI) in the diagnosis of occlusal caries. Methods: A total of 156 occlusal surfaces were investigated. Each occlusal surface was assessed with LED- and LF-based devices after a VI was performed. Pit and fissure opening was applied to the occlusal surfaces in which opacity or discoloration was distinctly visible after airdrying. The inter-examiner reliability of caries examination was assessed using the weighted kappa statistics. The sensitivity, specificity, and accuracy of occlusal caries diagnosis using these methods were calculated according to the appropriate thresholds. Results: Acceptable interexaminer agreement was found for the LED- and LF-based devices and VI (kappa = 0.61, kappa = 0.76, and kappa = 0.87, respectively). Higher specificity values were achieved at a T2 threshold for the LF-based device (0.76 and 0.80) and at a T1 threshold for the LED-based readings (0.60 and 0.62) and VI (0.90 and 0.93) for both observers. With regard to VI, higher sensitivity values were found at both thresholds for the two observers in comparing the three caries detection methods (0.98 at T1 and 0.96 at T2). The accuracy values for T1 were higher than those for the T2 values, for all three caries detection methods. Conclusions: Caries lesions may be detected more accurately than clinically sound areas by both caries detection devices.

| Hatay Mustafa Kemal Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Hatay Mustafa Kemal Üniversitesi, Hatay, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim