Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Gocmen, Orhan" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Performance of QuantiFERON-TB Gold In-Tube test and Tuberculin Skin Test for diagnosis of latent tuberculosis infection in BCG vaccinated health care workers
    (Int Scientific Information, Inc, 2014) Babayigit, Cenk; Ozer, Burcin; Inandi, Tacettin; Ozer, Cahit; Duran, Nizami; Gocmen, Orhan
    Background: Tuberculin skin test (TST) has been used for years as an aid in diagnosing latent tuberculosis infection (LTBI) but it suffers from a number of well-documented performance and logistic problems. Quantiferon-TB Gold In Tube test (QFT-GIT) has been reported to have better sensitivity and specifity than TST. In this study, it was aimed to compare the performance of a commercial IFN-gamma release assay (QFT-GIT) with TST in the diagnosis of HCWs at risk for latent TB infection in BCG vaccinated population. Material/Methods: Hundred healthy volunteer health care workers were enrolled. All were subjected to TST and QFT-GIT. Results were compared among Health Care Workers (HCWs) groups in terms of profession, workplace, working duration. Results: TST is affected by previous BCG vaccinations and number of cases with QFT-GIT positivity is increased in accordance with the TST induration diameter range. QFT-GIT result was negative in 17 of 32 TST positive (>= 15 mm) cases and positive in 4 of 61 cases whose TST diameters are between 6-14 mm, that is attritutable to previous BCG vaccination(s). It was negative in all cases with TST diameters between 0-5 mm. HCWs with positive QFT-GIT results were significantly older than the ones with negative results. Furthermore duration of work was significantly longer in QFT-GIT positive than in negative HCWs. Conclusions: There was a moderate concordance between QFT-GIT and TST, when TST result was defined as positive with a >= 15 mm diameter of induration. We suggest that QFT-GIT can be used as an alternative to TST for detection of LTBI, especially in groups with high risk of LTBI and in population with routine BCG vaccination program.

| Hatay Mustafa Kemal Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Hatay Mustafa Kemal Üniversitesi, Hatay, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim