Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Gueven, Esref Oguz" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Augmented Reality: A New Tool To Improve Surgical Accuracy during Laparoscopic Partial Nephrectomy? Preliminary In Vitro and In Vivo Results
    (Elsevier, 2009) Teber, Dogu; Guven, Selcuk; Simpfendoerfer, Tobias; Baumhauer, Mathias; Gueven, Esref Oguz; Yencilek, Faruk; Goezen, Ali Serdar
    Background: Use of an augmented reality (AR)-based soft tissue navigation system in urologic laparoscopic surgery is an evolving technique. Objective: To evaluate a novel soft tissue navigation system developed to enhance the surgeon's perception and to provide decision-making guidance directly before initiation of kidney resection for laparoscopic partial nephrectomy (LPN). Design, setting, and participants: Custom-designed navigation aids, a mobile C-arm capable of cone-beam imaging, and a standard personal computer were used. The feasibility and reproducibility of inside-out tracking principles were evaluated in a porcine model with an artificially created intraparenchymal tumor in vitro. The same algorithm was then incorporated into clinical practice during LPN. Interventions: Evaluation of a fully automated inside-out tracking system was repeated in exactly the same way for 10 different porcine renal units. Additionally, 10 patients underwent retroperitoneal LPNs under manual AR guidance by one surgeon. Measurements: The navigation errors and image-acquisition times were determined in vitro. The mean operative time, time to locate the tumor, and positive surgical margin were assessed in vivo. Results and limitations: The system was able to navigate and superpose the virtually created images and real-time images with an error margin of only 0.5 mm, and fully automated initial image acquisition took 40 ms. The mean operative time was 165 min (range: 135-195 min), and mean time to locate the tumor was 20 min (range: 1327 min). None of the cases required conversion to open surgery. Definitive histology revealed tumor-free margins in all 10 cases. Conclusions: This novel AR tracking system proved to be functional with a reasonable margin of error and image-to-image registration time. Mounting the pre- or intraoperative imaging properties on real-time videoendoscopic images in a real-time manner will simplify and increase the precision of laparoscopic procedures. (C) 2009 European Association of Urology Published by Elsevier B.V. All rights reserved.

| Hatay Mustafa Kemal Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Hatay Mustafa Kemal Üniversitesi, Hatay, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim