Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Koc, Mustafa" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus
    (Springer, 2021) Ozkan, Haci Hasan; Koc, Mustafa; Kiziltoprak, Hasan; Tekin, Kemal; Aydemir, Emre
    Purpose To investigate topographic, tomographic, topometric, densitometric, and aberrometric parameters in subclinical keratoconus with the Pentacam HR imaging system. Methods Data of 3128 patients were evaluated, finding in 108 patients clinical keratoconus in one eye and subclinical keratoconus in the other. Corneal topographic, tomographic, topometric, densitometric, and aberrometric values obtained using the Pentacam HR imaging system were compared between clinical keratoconus, subclinical keratoconus, and normal eyes. Results Comparing eyes with subclinical keratoconus and the control group, while flat K, horizontal coma, horizontal trefoil, and vertical trefoil values were similar (p > 0.05 for each), all other parameters were significantly different (p < 0.05 for each). Densitometry values of eyes with subclinical keratoconus were significantly higher in all layers of the 0-2 mm annular area and in the anterior and central layers of the 2-6 mm annular area compared to the control group (p < 0.05 for each). According to the receiver operating characteristic curve analysis, the densitometry region with the largest area under the curve was the anterior layer of the 0-2 mm annular area. The sensitivity in this region was 79.4% and the specificity 73.2% in distinguishing eyes with subclinical keratoconus from normal eyes when 19.3 GSU was considered the threshold. Conclusion Corneal densitometry values in the 0-2 and 2-6 mm annular areas, especially in the anterior layers, are parameters that can be used to predict and distinguish subclinical keratoconus from normal eyes.

| Hatay Mustafa Kemal Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Hatay Mustafa Kemal Üniversitesi, Hatay, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim