The Effect of Rotation Speed of XP-endo Shaper on Apically Extruded Debris During Endodontic Procedures: an In Vitro Study

dc.authoridTufenkci, Pelin/0000-0001-9881-5395
dc.contributor.authorYilmaz, Koray
dc.contributor.authorTufenkci, Pelin
dc.date.accessioned2024-09-18T20:15:02Z
dc.date.available2024-09-18T20:15:02Z
dc.date.issued2022
dc.departmentHatay Mustafa Kemal Üniversitesien_US
dc.description.abstractThe aim of this study was to evaluate the effect of using a higher rotation speed with the XP-endo Shaper (XPS) on apically extruded debris and operation time during endodontic treatment and retreatment procedures. Sixty mesial roots of mandibular first molar teeth were randomly assigned to four groups (Initial treatment groups: XPS used at 1000 or 3000rpm rotation speeds and Retreatment groups: XPS used at 1000 or 3000rpm rotation speeds). During the initial treatment and retreatment procedures preweighed eppendorf tubes were used to collect apically extruded debris, and the operation time was recorded in seconds. The extruded debris was quantified by subtracting the preinstrumentation from the postinstrumentation weight of the Eppendorf tubes. Data were analysed using two-way ANOVA at a significance level of 0.05. In all groups, the use of the XPS at 1000 or 3000rpm rotation speeds had no statistically significant effect on the amount of apically extruded debris (p>0.05). The use of the XPS at a 3000rpm rotation speed significantly decreased the instrumentation time (p<0.05). In summary, the use of the XPS at high rotation speeds in initial treatment and retreatment procedures did not have a significant effect on the amount of apically extruded debris but significantly decreased the operation time.en_US
dc.identifier.doi10.15517/IJDS.2021.47147
dc.identifier.endpage89en_US
dc.identifier.issn1659-1046
dc.identifier.issn2215-3411
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-85129755098en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage81en_US
dc.identifier.urihttps://doi.org/10.15517/IJDS.2021.47147
dc.identifier.urihttps://hdl.handle.net/20.500.12483/9398
dc.identifier.volume24en_US
dc.identifier.wosWOS:000793965300009en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherUniv Costa Rica, Fac Odontologiaen_US
dc.relation.ispartofOdovtos International Journal of Dental Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDebris extrusionen_US
dc.subjectEndodontic treatmenten_US
dc.subjectRetreatmenten_US
dc.subjectXP-endo Shaperen_US
dc.titleThe Effect of Rotation Speed of XP-endo Shaper on Apically Extruded Debris During Endodontic Procedures: an In Vitro Studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tam Metin / Full Text
Boyut:
224.46 KB
Biçim:
Adobe Portable Document Format