dc.description.abstractThe aim of this study was to investigate the effects of tube current and tube voltage choices on patient dose in adult and pediatric CT protocols by qualitative analysis using Principal Component Analysis (PCA), cluster analysis, and statistical analysis. Dose length product (DLP), Effective mAs (Eff. mAs), and volume-weighted CT dose index (CTDIvol) dose descriptors were obtained from 16 adult and pediatric head phantom CT examinations. Different tube voltage and tube current values were selected in both pediatric head and adult head CT imaging protocols, and PCA and cluster analysis were applied to the data obtained for qualitative analysis of the relationship between CTDIvol, Eff. mAs and Total DLP values. The two principial components (PC) with the highest values among those obtained as a result of the PCA method were used. PC1 was 70.97%, and PC2 was 28.03%. In the cluster analysis, it was observed that the values obtained from pediatric and adult phantom CT scans were classified into two different clusters. The correlation coefficient for adult patients was r = 0.998, and for pediatric patients, the correlation coefficient was r = 0.947. When the obtained clusters were examined, the degree of closeness or distance of the variables could be observed. In the study, as a result of the analysis of CTDIvol, Eff. mAs and Total DLP data based on manufacturer data at different kV and mA values with PCA and cluster analysis, it was shown that pediatric patients could be exposed to more radiation than the adult patients. Copyright © 2024 Health Physics Society.en_US
dc.identifier.doi10.1097/HP.0000000000001830
dc.identifier.endpage519en_US
dc.identifier.issn0017-9078
dc.identifier.issue4en_US
dc.identifier.pmid38787573en_US
dc.identifier.scopus2-s2.0-85202720960en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage513en_US
dc.identifier.urihttps://doi.org/10.1097/HP.0000000000001830
dc.identifier.urihttps://hdl.handle.net/20.500.12483/15225
dc.identifier.volume127en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherLippincott Williams and Wilkinsen_US
dc.relation.ispartofHealth Physicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectmedical radiationen_US
dc.subjectphantomen_US
dc.subjectradiation doseen_US
dc.subjectradiation risken_US
dc.titleInvestigating the Effects of Tube Current and Tube Voltage on Patient Dose in Computed Tomography Examinations with Principial Component Analysis and Cluster Analysis: Phantom Studyen_US
dc.typeArticleen_US

Dosyalar