Assessment of the mass attenuation parameters with using gamma-rays for manganese substituted nano hydroxyapatite

dc.authoridKOKSAL, Oguz Kagan/0000-0003-2671-6683
dc.authoridCengiz, Erhan/0000-0002-4094-5784
dc.authoridApaydin, Gokhan/0000-0002-4647-344X
dc.contributor.authorKoksal, O. K.
dc.contributor.authorApaydin, G.
dc.contributor.authorTozar, A.
dc.contributor.authorKarahan, I. H.
dc.contributor.authorCengiz, E.
dc.date.accessioned2024-09-18T20:25:16Z
dc.date.available2024-09-18T20:25:16Z
dc.date.issued2019
dc.departmentHatay Mustafa Kemal Üniversitesien_US
dc.description.abstractManganese substituted hydroxyapatite nanoparticles (nMnHAp) were produced using the ultrasonic wet chemical method. The elemental analysis was performed using Scanning Electron Microscopy (SEM) with integrated Energy Dispersive X-ray Spectrometry (EDX). The mass attenuation coefficients of manganese substituted hydroxyapatite nanoparticles have been measured at 59.5 keV gamma energy emitted from Am-241 radioisotope annular source with 50 mCi activity by using Ultra Low Energy Germanium Detector. These values are found to be in good agreement with theoretical values based on calculated XCOM data. Electron densities and effective atomic numbers were calculated by using the mass attenuation coefficients. Also, the mass attenuation coefficient of the real bone was determined as experimentally. The obtained results may provide information on how much radiation is transmitted through the sample when they are exposed to gamma-rays at 59.5 keV by comparing real bone.en_US
dc.identifier.doi10.1016/j.radphyschem.2019.02.040
dc.identifier.endpage80en_US
dc.identifier.issn0969-806X
dc.identifier.scopus2-s2.0-85062721508en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage76en_US
dc.identifier.urihttps://doi.org/10.1016/j.radphyschem.2019.02.040
dc.identifier.urihttps://hdl.handle.net/20.500.12483/10209
dc.identifier.volume159en_US
dc.identifier.wosWOS:000472690000011en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofRadiation Physics and Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGamma-Ray Attenuationen_US
dc.subjectManganese Substituted Nano Hydroxyapatiteen_US
dc.subjectReal Boneen_US
dc.subjectElectron Densityen_US
dc.subjectEffective Atomic Numberen_US
dc.titleAssessment of the mass attenuation parameters with using gamma-rays for manganese substituted nano hydroxyapatiteen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ N/A ]
İsim:
Tam Metin / Full Text
Boyut:
941.67 KB
Biçim:
Adobe Portable Document Format