Use of Gaussian-type functions for flux-based dose calculations in carbaon ion therapy

dc.authoridUsta, Metin/0000-0002-7896-397X
dc.contributor.authorUsta, Metin
dc.contributor.authorAydin, Gural
dc.date.accessioned2024-09-18T20:06:30Z
dc.date.available2024-09-18T20:06:30Z
dc.date.issued2020
dc.departmentHatay Mustafa Kemal Üniversitesien_US
dc.description.abstractIn radiation therapy, it is very important to ensure that the radiation dose is correctly delivered to the patient. This is achieved by obtaining quantitative dose measurements for beam calibration in the treatment planning system. Dose calculations should be performed with the required accuracy to a degree of uncertainty of less than 1%. The measurement of the absorbed dose in and around body tissues irradiated with carbon ions requires careful use of materials selected from established phantom and radiation detectors. The main advantage of such materials is that when information on the energy and nature of charged particles at the desired point is incomplete or inaccurate, they can allow determination of the absorbed dose. In general, radiation interactions in a tissue representation caused by carbon ions can be characterized by calculating the linear stopping power. Carbon ions have a limited penetration depth within human tissues that depends on the energy and stopping power of these ions as they penetrate into the body. The purpose of the present study was to calculate the stopping power, range and dose to intestinal and prostate tissues of carbon ions. The stopping power values of these tissues were specified by the effective charge approach method. The 5ZaPa-NR-CV, pcemd-4 and pcSseg-4 sets of Gaussian-type functions were employed for the calculation of electronic charge density. Range calculations were made by means of the Gaussian quadrature method, making use of the continuous slowing down approximation. Flux-based dose calculations were also carried out in accordance with the Bragg-Gray theorem using the Geant4 and FLUKA simulation toolkits. The results were compared with each other and with the SRIM and CasP datasets. Then, depth-dose distributions and range values were verified by positron emission activity using the GATE toolkit. Among the different types of Gaussian functions used here, the best semi-analytical result was found for the 5ZaPa-NR-CV set. The results obtained in the present study can be used for dose verification and dose reconstruction in charged particle radiotherapy and for radiation research on the interaction of radiation with matter. The results calculated here will be useful for quantifying uncertainties associated with stopping power, range, and reconstruction of dose in charged particle therapy.en_US
dc.description.sponsorshipMustafa Kemal University Scientific Research Projects (BAP) [18.M.098]en_US
dc.description.sponsorshipThis study was supported by the 18.M.098 project within the scope of Mustafa Kemal University Scientific Research Projects (BAP).en_US
dc.identifier.doi10.1007/s00411-020-00856-9
dc.identifier.endpage522en_US
dc.identifier.issn0301-634X
dc.identifier.issn1432-2099
dc.identifier.issue3en_US
dc.identifier.pmid32561981en_US
dc.identifier.scopus2-s2.0-85086744707en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage511en_US
dc.identifier.urihttps://doi.org/10.1007/s00411-020-00856-9
dc.identifier.urihttps://hdl.handle.net/20.500.12483/8551
dc.identifier.volume59en_US
dc.identifier.wosWOS:000543633500001en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofRadiation and Environmental Biophysicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCarbon ion therapyen_US
dc.subjectStopping poweren_US
dc.subjectRangeen_US
dc.subjectRadiation doseen_US
dc.subjectPETen_US
dc.titleUse of Gaussian-type functions for flux-based dose calculations in carbaon ion therapyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ N/A ]
İsim:
Tam Metin / Full text
Boyut:
1.25 MB
Biçim:
Adobe Portable Document Format