Vacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual Irrigation and Aspiration System of Phaco Machine in Immature Cataract

dc.authoridAyintap, Emre/0000-0002-7537-2672
dc.contributor.authorOksuz, Huseyin
dc.contributor.authorDaglioglu, Mutlu C.
dc.contributor.authorCoskun, Mesut
dc.contributor.authorIlhan, Ozgur
dc.contributor.authorTuzcu, Esra Ayhan
dc.contributor.authorIlhan, Nilufer
dc.contributor.authorAyintap, Emre
dc.date.accessioned2024-09-18T21:06:27Z
dc.date.available2024-09-18T21:06:27Z
dc.date.issued2013
dc.departmentHatay Mustafa Kemal Üniversitesien_US
dc.description.abstractSeventy-eight eye of 65 patients were enrolled in this retrospective clinical study. Two-side ports are made with a 23-gauge stiletto knife. The irrigation handpiece is introduced into the anterior chamber through one side port and 27-gauge cystotome is introduced through the other one. Anterior capsular flap is created with cystotome. The capsular flap is vacuumed with a 25-gauge visco elastic's cannula, which connected to the phaco machine vacuum. The continuous circular capsulorhexis (CCC) is completed with the using bimanual irrigation and aspiration system of phaco machine. Vacuum-assisted CCC technique was used in 78 cases of uncomplicated immature senile cataracts. All cases were done under sub-Tenon's anesthesia. A complete CCC was achieved in all cases. Performing CCC with our technique is easy, safe, and cheap. It may be an alternative method to CCC by using OVD and forceps.en_US
dc.identifier.doi10.1155/2013/921646
dc.identifier.issn2090-004X
dc.identifier.issn2090-0058
dc.identifier.pmid24303209en_US
dc.identifier.scopus2-s2.0-84888857191en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.urihttps://doi.org/10.1155/2013/921646
dc.identifier.urihttps://hdl.handle.net/20.500.12483/13610
dc.identifier.volume2013en_US
dc.identifier.wosWOS:000327203900001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherHindawi Ltden_US
dc.relation.ispartofJournal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleVacuum-Assisted Continuous Circular Capsulorhexis Using Bimanual Irrigation and Aspiration System of Phaco Machine in Immature Cataracten_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tam Metin / Full Text
Boyut:
1.66 MB
Biçim:
Adobe Portable Document Format