Radiation transmission of heavyweight and normal-weight concretes containing colemanite for 6 MV and 18 MV X-rays using linear accelerator
Yükleniyor...
Tarih
2010
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Pergamon-Elsevier Science Ltd
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Accurate measurements have been made to determine radiation transmission of concretes produced with barite, colemanite and normal aggregate by using beam transmission method for 6 and 18 MV X-rays with a linear accelerator (LINAC). Linear attenuation coefficients of thirteen heavy- and four normal-weight concretes were calculated. It was determined that linear attenuation coefficient (mu, cm(-1)) decreased with colemanite concentration and increased with barite concentration in both types of the concretes. (C) 2009 Elsevier Ltd. All rights reserved.
Açıklama
Anahtar Kelimeler
Gamma-Rays, Attenuation, Neutrons, Shields
Kaynak
Annals of Nuclear Energy
WoS Q Değeri
Q3
Scopus Q Değeri
Q1
Cilt
37
Sayı
3