Does subthalamic nucleus deep brain stimulation affect the static balance at different frequencies?
dc.authorid | Oz, Fatma/0000-0001-5747-9989 | |
dc.authorid | YUCEKAYA, BIRCAN/0000-0002-2015-2744 | |
dc.authorid | Huzmeli, Irem/0000-0003-3400-6016 | |
dc.authorid | YILMAZ, Atilla/0000-0002-1081-3545 | |
dc.contributor.author | Oz, Fatma | |
dc.contributor.author | Yucekeya, Bircan | |
dc.contributor.author | Huzmeli, Irem | |
dc.contributor.author | Yilmaz, Atilla | |
dc.date.accessioned | 2024-09-18T20:53:06Z | |
dc.date.available | 2024-09-18T20:53:06Z | |
dc.date.issued | 2023 | |
dc.department | Hatay Mustafa Kemal Üniversitesi | en_US |
dc.description.abstract | Purpose: To investigate the effects of bilateral subthalamic nucleus deep brain stimulation (STN-DBS) with different stimulation frequencies on static balance. Materials and methods: Twenty patients (15 males and 5 females), aged between 43 and 81 (mean: 60.05 +/- 7.4) years, who had been diagnosed with idiopathic Parkinson's disease (PD) and undergone STN-DBS surgery were included in the study. Static balance was assessed with TecnoBody Rehabilitation System at four different frequencies: 230, 130, 90 and 60 Hz and off-stimulation. Static balance tests were 'stabilometric test, stabilometric compared bipedal closed/opened eye, stabilometric compared mono pedal (right/left foot)'. These tests reported the centre of pressure data 'ellipse area, perimeter, front/back and mediolateral standard deviations'. Results: There were no statically differences between the static balance test results at any frequency (p > 0.05), but results were found better at 90 Hz. Stabilometric compared bipedal opened eye forward-backward standard deviation result was significant between off -stimulation and 130 Hz (p = 0.04). Different frequency stimulation affected the static balance categories percentage with no statistical significance between off-stimulation and others (all p > 0.05). Conclusion: This study showed that STN-DBS did not affect the static balance negatively. Low -frequency (LF) stimulation improved the static equilibrium. Posturography systems will give more precise and quantitative results in similar studies with wide frequency ranges. (c) 2022 Sociedad Espa nola de Neurocirugi ' a. Published by Elsevier Espa n similar to a, S.L.U. All rights reserved. | en_US |
dc.identifier.doi | 10.1016/j.neucir.2022.01.001 | |
dc.identifier.endpage | 66 | en_US |
dc.identifier.issn | 1130-1473 | |
dc.identifier.issn | 2340-6305 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-85125436920 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 60 | en_US |
dc.identifier.uri | https://doi.org/10.1016/j.neucir.2022.01.001 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12483/11578 | |
dc.identifier.volume | 34 | en_US |
dc.identifier.wos | WOS:000990716500001 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Espana Slu | en_US |
dc.relation.ispartof | Neurocirugia | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Parkinson's disease | en_US |
dc.subject | Subthalamic nucleus deep brain | en_US |
dc.subject | stimulation | en_US |
dc.subject | Static balance | en_US |
dc.subject | Stimulation frequency | en_US |
dc.title | Does subthalamic nucleus deep brain stimulation affect the static balance at different frequencies? | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1