Production and Mechanical Behaviour of Biomedical CoCrMo Alloy
Yükleniyor...
Tarih
2011
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Iop Publishing Ltd
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Cobalt-based alloy (Co-30Cr-5.5Mo) is produced by the investment casting process. This alloy complies with the ASTM F75 standard and is widely used in the manufacturing of orthopedic implants because of its high strength, good corrosion resistance and excellent biocompatibility properties. SEM, XRD and microhardness tests are used to examine the mechanical properties of the material. The examined material exhibits the behaviour of indentation size effect (ISE). Our results reveal that Vickers and Knoop microhardness are dependent on indentation test load. The traditional Meyer's law, the proportional specimen resistance (PSR) model and the Hays-Kendall model (HK) are used to analyze the load dependence of the hardness. As a result, the Hays-Kendall model is found to be the most effective to determine the load-independent hardness H-LI of CoCrMo alloy.
Açıklama
Anahtar Kelimeler
Low-Load Hardness, Indentation, Microhardness
Kaynak
Chinese Physics Letters
WoS Q Değeri
Q3
Scopus Q Değeri
Q1
Cilt
28
Sayı
12