Alloying effect on K-shell fluorescence parameters of porous NiTi shape memory alloys
dc.authorid | Ozkendir, Osman Murat/0000-0002-0810-9938 | |
dc.authorid | Kaya, Mehmet/0000-0001-9710-2254 | |
dc.authorid | Kimura, Shin-ichi/0000-0003-1091-196X | |
dc.authorid | Ozkendir, Osman Murat/0000-0003-3749-5441 | |
dc.authorid | Hajiri, Tetsuya/0000-0003-3770-483X | |
dc.authorid | Cengiz, Erhan/0000-0002-4094-5784 | |
dc.contributor.author | Cengiz, E. | |
dc.contributor.author | Ozkendir, O. M. | |
dc.contributor.author | Kaya, M. | |
dc.contributor.author | Tirasoglu, E. | |
dc.contributor.author | Karahan, I. H. | |
dc.contributor.author | Kimura, S. | |
dc.contributor.author | Hajiri, T. | |
dc.date.accessioned | 2024-09-18T19:52:37Z | |
dc.date.available | 2024-09-18T19:52:37Z | |
dc.date.issued | 2014 | |
dc.department | Hatay Mustafa Kemal Üniversitesi | en_US |
dc.description.abstract | The K-alpha,K-beta shell production cross-sections and K-beta/K-alpha intensity ratios of porous Ni -49 at% Ti shape memory alloys were determined using energy dispersive X-ray fluorescence (EDXRF) technique. Also, the alloying effect on the K shell fluorescence parameters was investigated. The samples were excited by 59.5 key gamma-rays from an Am-241 annular radioactive source. The K X-rays emitted by the samples were counted by an Ultra-LEGe detector with a resolution of 150 eV at 5.9 key. The structure analyses of the samples were also made using X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The deviations between the present results and theoretical values, calculated for pure Ti and Ni, were attributed to charge transfer phenomena and/or rearrangement of valance shell electrons and porosity. (C) 2014 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.doi | 10.1016/j.elspec.2014.01.002 | |
dc.identifier.endpage | 60 | en_US |
dc.identifier.issn | 0368-2048 | |
dc.identifier.issn | 1873-2526 | |
dc.identifier.scopus | 2-s2.0-84893667106 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 55 | en_US |
dc.identifier.uri | https://doi.org/10.1016/j.elspec.2014.01.002 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12483/7560 | |
dc.identifier.volume | 192 | en_US |
dc.identifier.wos | WOS:000335546500010 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science Bv | en_US |
dc.relation.ispartof | Journal of Electron Spectroscopy and Related Phenomena | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Alloying effect | en_US |
dc.subject | Production cross-section | en_US |
dc.subject | Intensity ratio | en_US |
dc.subject | Porous NiTi alloy | en_US |
dc.title | Alloying effect on K-shell fluorescence parameters of porous NiTi shape memory alloys | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
[ N/A ]
- İsim:
- 7560.pdf
- Boyut:
- 659.23 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text