The effects of air velocity on the performance of pad evaporative cooling systems

dc.authoridKARACA, CENGIZ/0000-0001-5161-1512
dc.contributor.authorDagtekin, Metin
dc.contributor.authorKaraca, Cengiz
dc.contributor.authorYildiz, Yilmaz
dc.contributor.authorBascetincelik, Ali
dc.contributor.authorPaydak, Omer
dc.date.accessioned2024-09-18T20:53:04Z
dc.date.available2024-09-18T20:53:04Z
dc.date.issued2011
dc.departmentHatay Mustafa Kemal Üniversitesien_US
dc.description.abstractThe aim of this study is to determine the relationship that is found among the velocity of the air passing through the pad, the obtained decrease at the temperature of the air passing the pad and the cooling efficiency at the cellulose based evaporative cooling pad, and be of help to the people who designed and operate these systems. In this study, cellulose based evaporative cooling pad (CELdek (R)7060-15, Munters AB, Kista, Sweden) was used and the tests conducted were completed at 2 periods. Air velocities were determined as 0.5, 1.0 and 1.5 ms(-1) at the first period, and 0.75, 1.25 and 1.75 ms(-1) at the second period. The water flow rate at the air velocities, chosen for both periods, was selected as 4 Lmin(-1)m(-2). As a result of the research, it was determined that it was not possible to make a mathematical connection among velocities of the air passing through the pad, obtained decrease at the temperature of the air passing the pad and the cooling efficiency. However, it can be said that the most appropriate air velocity for the pad used in the test should be higher than 0.5 ms(-1) and lower than 1.5 ms(-1).en_US
dc.identifier.endpage1822en_US
dc.identifier.issn1991-637X
dc.identifier.issue7en_US
dc.identifier.scopus2-s2.0-79956339234en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage1813en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12483/11564
dc.identifier.volume6en_US
dc.identifier.wosWOS:000292265600025en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherAcademic Journalsen_US
dc.relation.ispartofAfrican Journal of Agricultural Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPad evaporative coolingen_US
dc.subjectair velocityen_US
dc.titleThe effects of air velocity on the performance of pad evaporative cooling systemsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tam Metin / Full Text
Boyut:
1.16 MB
Biçim:
Adobe Portable Document Format