Effect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crowns

dc.authoridOzcelik, Tuncer Burak/0000-0001-5685-4409
dc.authoridYilmaz, Burak/0000-0002-7101-363X
dc.authoridKALE, Ediz/0000-0001-8761-0298
dc.contributor.authorKale, Ediz
dc.contributor.authorYilmaz, Burak
dc.contributor.authorSeker, Emre
dc.contributor.authorOzcelik, Tuncer Burak
dc.date.accessioned2024-09-18T21:03:09Z
dc.date.available2024-09-18T21:03:09Z
dc.date.issued2017
dc.departmentHatay Mustafa Kemal Üniversitesien_US
dc.description.abstractStatement of problem. Monolithic zirconia crowns fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology have recently become an alternative dental prosthetic treatment. The marginal fit of monolithic zirconia crown may be affected by different stages of the fabrication procedures in the laboratory and cementation. Information regarding the accuracy of fit of monolithic zirconia crowns at different stages of fabrication and cementation is limited. Purpose. The purpose of this in vitro study was to evaluate the effect of different stages of fabrication and cementation on the vertical marginal discrepancy (VMD) of CAD-CAM fabricated monolithic zirconia crowns. Material and methods. Six ivorine right maxillary first molar typodont teeth with standardized anatomic preparations for complete coverage ceramic crowns were scanned with a 3-dimensional laboratory scanner. Crowns were designed using CAD software and milled from presintered monolithic zirconia blocks in a 5-axis dental milling machine. A cement space of 25 pm for the margins and a 50-gm space starting 1 mm above the finish lines of the teeth were virtually set in the CAD software. A total of 144 measurements were performed on 6 specimens with 8 measurement locations in 3 different stages using stereoscopic zoom microscopy; after initial production of the crowns (post-sintering group), after glazing (post-glazing group), and after cementation (post-cementation group). The VMD values were statistically analyzed with 1-way repeated measures ANOVA and the Holm-Sidak method (alpha=.05). Results. Different stages of fabrication and cementation significantly affected the VMD of tested crowns (P=.003). The mean VMD was 38 gm for post-sintering group, 38 pm for post-glazing group, and 60 mu m for post-cementation group, with statistical differences between the post-sintering group, the post-cementation group (P<.002), and the post-glazing group and post-cementation group (P<.003); there were no statistical differences between the post-sintering group and the post-glazing group (P=.966). Conclusions. Within the limitations of this in vitro study, glazing did not significantly change the VMD of CAD-CAM monolithic zirconia crowns. Cementation significantly increased the VMD values.en_US
dc.identifier.doi10.1016/j.prosdent.2017.01.004
dc.identifier.endpage741en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue6en_US
dc.identifier.pmid28434679en_US
dc.identifier.scopus2-s2.0-85018624872en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage736en_US
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2017.01.004
dc.identifier.urihttps://hdl.handle.net/20.500.12483/13280
dc.identifier.volume118en_US
dc.identifier.wosWOS:000418394700010en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFixed Dental Prosthesesen_US
dc.subjectAll-Ceramic Crownsen_US
dc.subjectFracture-Resistanceen_US
dc.subjectIn-Vitroen_US
dc.subjectSingle Crownsen_US
dc.subjectMolar Crownsen_US
dc.subjectPartial Denturesen_US
dc.subjectCopingsen_US
dc.subjectThicknessen_US
dc.subjectRestorationsen_US
dc.titleEffect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crownsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ N/A ]
İsim:
Tam Metin / Full Text
Boyut:
1.31 MB
Biçim:
Adobe Portable Document Format