Comparison eCAP and behaviour thresholds in post lingual medel cochlear implant users

dc.authorid0000-0001-6380-3300en_US
dc.authorid0000-0001-8552-2403en_US
dc.contributor.authorSaraç, Elif Tuğba
dc.contributor.authorDeniz, Hüseyin
dc.contributor.authorOkuyucu, Şemsettin
dc.date.accessioned2020-12-25T09:30:55Z
dc.date.available2020-12-25T09:30:55Z
dc.date.issued2020en_US
dc.departmentTayfur Ata Sökmen Tıp Fakültesien_US
dc.description.abstractAim: Our purpose with this study is to determine the most effective and suitable cochlear implant programming method for CI users’ implants to experience quality hearing and for the users to achieve efficiency from their implants. Materials and Methods:Twenty-five cochlear implant users with post lingual progressive hearing loss were included in the study. Twelve electrodes’ ART (auditory nerve response telemetry) thresholds were determined and were statistically analyzed to be evaluated in the study. For 12 electrodes whose AutoART threshold was determined, the MCLs (most comfortable loudness) were determined behaviorally. Results: No correlations were found between the 12 electrodes and AutoART. It was seen that there was a correlation between the pure tone average obtained from 500-1000-2000 and 4000Hz and the speech reception threshold. Conclusion: The use of two test batteries together to determine thresholds can be helpful in the programming of the speech processor. The more audiologists work with cochlear implant patients and do programming, the more they accumulate data and gain occupational experience. With the occupational experience acquired in this manner, more accurate programming can be done.en_US
dc.identifier.doi10.5455/annalsmedres.2020.04.323en_US
dc.identifier.endpage1709en_US
dc.identifier.issn2636-7688
dc.identifier.issue6en_US
dc.identifier.startpage1704en_US
dc.identifier.trdizinid382830en_US
dc.identifier.urihttps://dx.doi.org/10.5455/annalsmedres.2020.04.323
dc.identifier.urihttps://hdl.handle.net/20.500.12483/3098
dc.identifier.volume27en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.publisherİnönü Üniversitesi Tıp Fakültesien_US
dc.relation.ispartofAnnals of Medical Researchen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBehavioral testen_US
dc.subjectCochlear implanten_US
dc.subjecteCAPen_US
dc.subjectSubjective testen_US
dc.subjectObjective testen_US
dc.titleComparison eCAP and behaviour thresholds in post lingual medel cochlear implant usersen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Sarac-Elif-Tugba-2020.pdf
Boyut:
177.91 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ N/A ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: