Effects of millimetric shifts in breast cancer radiotherapy on the radiation dose distribution
dc.authorscopusid | 57189073280 | |
dc.authorscopusid | 57189067038 | |
dc.authorscopusid | 57192234472 | |
dc.contributor.author | Sanli, Yusuf Tolga | |
dc.contributor.author | Cukurcayir, Funda | |
dc.contributor.author | Abacigil, Fatma | |
dc.date.accessioned | 2024-09-19T15:45:22Z | |
dc.date.available | 2024-09-19T15:45:22Z | |
dc.date.issued | 2016 | |
dc.department | Hatay Mustafa Kemal Üniversitesi | en_US |
dc.description.abstract | Background: This study aimed to facilitate decision-making in cases of breast cancer radiotherapy shifts by simulating millimetric shifts and analyzing their effects on dose distribution. Methods: The study included 30 patients with left side breast cancer who were treated with three dimensional conformal radiotherapy (3D-CRT) in the Radiation Oncology Department in Hatay Public Hospital, between January 2013 and April 2015. A treatment plan shifting at three axes with six different measures was simulated. Results: The biggest difference in values was (+3mm shift) 476cGy, with a 7.7 % change for heart and 25.6% for spinal cord. The shifts in values respectively for CTV min, mean, max were -4.8%, 2.5%, 4%. The differences for lymphatic min, mean, max were 21.3%, 20.3%, -12.2%. Conclusion: The most important thing is not the treatment plan quality, but its practicality. The treatment plan must be practical and its practice must be controlled rigidly. | en_US |
dc.identifier.doi | 10.7314/APJCP.2016.17.3.1197 | |
dc.identifier.endpage | 1199 | en_US |
dc.identifier.issn | 1513-7368 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.pmid | 27039748 | en_US |
dc.identifier.scopus | 2-s2.0-84965071670 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 1197 | en_US |
dc.identifier.uri | https://doi.org/10.7314/APJCP.2016.17.3.1197 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12483/14617 | |
dc.identifier.volume | 17 | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Asian Pacific Organization for Cancer Prevention | en_US |
dc.relation.ispartof | Asian Pacific Journal of Cancer Prevention | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Breast cancer | en_US |
dc.subject | Millimetric shifts | en_US |
dc.subject | Radiation dose distribution | en_US |
dc.subject | Radiotherapy | en_US |
dc.title | Effects of millimetric shifts in breast cancer radiotherapy on the radiation dose distribution | en_US |
dc.type | Article | en_US |