Repair of Iridodialysis Using 8-0 Polypropylene
Yükleniyor...
Dosyalar
Tarih
2014
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Taylor & Francis Inc
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Purpose: Investigate the effectiveness of repair of iridodialysis with 8-0 polypropylene. Methods: We present four cases of traumatic iridodialysis that were repaired by 8-0 polypropylene suture. Results: Better iris reposition and stability were achieved with 8-0 polypropylene suture despite wide degree traumatic iridodialysis in all patients. Conclusion: In this study, we used 8-0 polypropylene suture, which is thicker, cheaper, and more durable than 10-0 sutures. We suggest that usage of 8-0 polypropylene sutures may provide better iris repositioning.
Açıklama
Anahtar Kelimeler
8-0 polypropylene suture, 27-gauge needle, iridodialysis, ocular trauma, repair