Repair of Iridodialysis Using 8-0 Polypropylene
dc.authorid | Ayintap, Emre/0000-0002-7537-2672 | |
dc.contributor.author | Daglioglu, Mutlu Cihan | |
dc.contributor.author | Coskun, Mesut | |
dc.contributor.author | Ilhan, Nilufer | |
dc.contributor.author | Ayintap, Emre | |
dc.contributor.author | Tuzcu, Esra Ayhan | |
dc.contributor.author | Ilhan, Ozgur | |
dc.contributor.author | Oksuz, Huseyin | |
dc.date.accessioned | 2024-09-18T19:47:58Z | |
dc.date.available | 2024-09-18T19:47:58Z | |
dc.date.issued | 2014 | |
dc.department | Hatay Mustafa Kemal Üniversitesi | en_US |
dc.description.abstract | Purpose: Investigate the effectiveness of repair of iridodialysis with 8-0 polypropylene. Methods: We present four cases of traumatic iridodialysis that were repaired by 8-0 polypropylene suture. Results: Better iris reposition and stability were achieved with 8-0 polypropylene suture despite wide degree traumatic iridodialysis in all patients. Conclusion: In this study, we used 8-0 polypropylene suture, which is thicker, cheaper, and more durable than 10-0 sutures. We suggest that usage of 8-0 polypropylene sutures may provide better iris repositioning. | en_US |
dc.identifier.doi | 10.3109/08820538.2013.796395 | |
dc.identifier.endpage | 162 | en_US |
dc.identifier.issn | 0882-0538 | |
dc.identifier.issn | 1744-5205 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.pmid | 23879224 | en_US |
dc.identifier.scopus | 2-s2.0-84907300480 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 159 | en_US |
dc.identifier.uri | https://doi.org/10.3109/08820538.2013.796395 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12483/7260 | |
dc.identifier.volume | 29 | en_US |
dc.identifier.wos | WOS:000334681100008 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Taylor & Francis Inc | en_US |
dc.relation.ispartof | Seminars in Ophthalmology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | 8-0 polypropylene suture | en_US |
dc.subject | 27-gauge needle | en_US |
dc.subject | iridodialysis | en_US |
dc.subject | ocular trauma | en_US |
dc.subject | repair | en_US |
dc.title | Repair of Iridodialysis Using 8-0 Polypropylene | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
[ N/A ]
- İsim:
- 7260.pdf
- Boyut:
- 438.3 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text